Gulf of Mexico Operator Automates Riser Annulus Monitoring

  • FlexSentinel® gave a GoM operator real-time riser anomaly detection.
  • Its early detection enabled cost-effective repairs, preventing serious failures.
  • Success spurred repeat FlexSentinel® orders; custom monitoring also averted ruptures.

A Tier 1 Gulf of Mexico operator approached Flexlife to provide a permanent real-time vent gas monitoring system to assist with maintaining the integrity and safe operation of their flexible risers. Flexlife designed a tailor-made FlexSentinel® system to comply with the operator’s specifications. The operator placed an order for three of these systems to monitor two flexible risers each on three platforms. The system provides vent gas flow, pressure and temperature data is used to almost instantaneously detect the occurrence of anomalies such as a blockage in the venting system and a breach in the riser outer sheath.

The deployment of the FlexSentinel® Vent Gas Monitoring System thus allows operators to detect such anomalies and carry out relatively cheap and efficient repairs before these anomalies grow into more serious and more expensive failure modes.
Flexlife offers a turnkey solution, providing tailor-made designs, purchase of components, fabrication and FAT, and also offshore baseline annulus testing of the risers and commissioning of the FlexSentinel® Vent Gas Monitoring System.
Following the installation of the original three FlexSentinels® last year, the operator has recently ordered a new FlexSentinel® to monitor two new flexible risers being tied-back to another platform.

Vent Gas Monitoring System Protects Riser from Annulus Over-pressurisation

The Problem

The Solution

We designed, manufactured and tested a simple Annulus Vent Gas Monitoring System which offered the required functionality without extraneous features. It is cost effective and provides continuous monitoring of the riser annulus permeation rates. More importantly, if the vent system blockage worsened, the operator could immediately install a FlexDefend® riser annulus venting collar before the outer sheath could rupture.